Skip to main content
Latchways® Roof Light Covers

Latchways® Roof Light Covers

Falls through fragile surfaces are one of the biggest causes of accident when it comes to working at height. Rooflights when flush or inplane can be difficult to differentiate from the roof surface. The MSA Latcwhays Roof Light Covers are a simple solution to provide protection to workers when there is presence of fragile surfaces. This Skylight protection is simply installed over the fall hazard creating a certified protective surface incase of an individual or an object falling.

Show Less
Read More
Latchways® Roof Light Covers
Latchways® Roof Light Covers
Highlights
Videos
Specifications
Approvals
Literature
Highlights
  • Flexible - Standard panel sizes ranging from 1m-3m in length, bespoke options available to suit most different roof light types and configurations
  • 'Class A' Non-Fragile Assembly - Independently tested in accordance with the 'ACR(M) 001 2014 Test for Non-Fragility of Large Element Roof Assemblies'
  • Modular—Quick and easy to install, panels can be joined to together to form long runs
  • Corrosion and Moisture resistant—Roof Light Covers are manufactured from extruded PVCu planks and support leavers, injection moulded -PVCu end caps with stainless steel fixings and fasteners
  • Durability—Lifespan in excess of 25 years (BBA Certified)
  • Manufactured from recycled PVCu for a lightweight and environmentally considerate solution
  • Compatibility—Designed to work with all major roof types
Videos
Show More Videos
Show Less Videos
Specifications
Applications
Working at Heights
Approvals / Standards
*Non- Fragile - Independently tested in accordance with the 'ACR(M) 001 2014 Test for Non-Fragility of Large Element Roof Assemblies'
*Bespoke/prefabricated test compliance—Roof Light Covers meet the standard: Pre-Fabricated Accessory EN516 – Class 1-C
*Resistance to Impact: Soft body to MOAT 11:3.1.13 Hard body to MOAT 11:3.1.1.5
*Tensile Impact Strength: BS2782-3.354(A)
*Fire resistant—Roof Light Covers are fire resistant and self-extinguishing—complies with BS465 part 71987 – Class 1 (Y)
*Severe UV exposure tested—Roof Light Covers have undergone the European Organisation for Technical Approvals (EOTA) TR 010 25 year severe climate exposure test. As such, the product has been classified “S” for use in severe climates
Markets
Construction
General Industry
Approvals
Approvals subject to change without notice and may differ based on configuration, part number and/or country. Contact Customer Service or check approval label on product for specific approval information.
Literature
Part Number(s)
Latchways® Roof Light Covers
COVER7
COVER7
Roof Light Cover for Fibre Cement Roofs
COVER7
Roof Light Cover for Fibre Cement Roofs
Min QTY: 1
QTY Increments: 1
COVER8
COVER8
Roof Light Cover for Vertical Glazing
COVER8
Roof Light Cover for Vertical Glazing
Min QTY: 1
QTY Increments: 1
COVER9
COVER9
Fall Proof Cover for Asbestos Roofs
COVER9
Fall Proof Cover for Asbestos Roofs
Min QTY: 1
QTY Increments: 1
COVER10
COVER10
Partial Cover for Restraint Systems
COVER10
Partial Cover for Restraint Systems
Min QTY: 1
QTY Increments: 1
COVER1
COVER1
Roof Light Cover on Trapezoidal Industrial roofs
COVER1
Roof Light Cover on Trapezoidal Industrial roofs
Min QTY: 1
QTY Increments: 1
COVER2
COVER2
Roof Light Cover on Standing Seam Roof
COVER2
Roof Light Cover on Standing Seam Roof
Min QTY: 1
QTY Increments: 1
COVER3
COVER3
Raised Cover for Domed Roof Lights
COVER3
Raised Cover for Domed Roof Lights
Min QTY: 1
QTY Increments: 1
COVER4
COVER4
Raised Cover for Solar PV Protection
COVER4
Raised Cover for Solar PV Protection
Min QTY: 1
QTY Increments: 1
COVER5
COVER5
Raised Cover for Bespoke Roof Lights
COVER5
Raised Cover for Bespoke Roof Lights
Min QTY: 1
QTY Increments: 1
COVER6
COVER6
Roof Light Cover with Walksafe
COVER6
Roof Light Cover with Walksafe
Min QTY: 1
QTY Increments: 1

Ask a Question


Thank you! An MSA representative will be in touch soon.
Un représentant de MSA vous contactera bientôt.
Ein MSA-Ansprechpartner wird sich in Kürze bei Ihnen melden.